Recorders
Graphic Recorders |
 |
 | |
 |
|
.gif) .gif)
|
BR Series Graphic
Recorders |
|
|
|
| The BR series, new
graphic recorders for the next generation, fit various
applications in industrial fields to test/research fields. The
measured data are displayed on a 5.5" TFT color LCD display,
stored into the internal flash memory and can be saved to a
3.5" floppy disk. You can convert electronic data to a popular
spreadsheet software by using the optional software [PASS].
The MODBUS communications link to computer systems makes the
configuration with your personal computer easy. The recorders
need no consumable costs including chart papers and inks used
in conventional recorders. |
 |
|
Features
- Wide range of display
functions
Points can
be classified into maximum 5 groups and a trend screen, a
data screen, a bargraph screen or a multi-screen can be
displayed for each group. A historical trend screen, a
real-time/historical trend screen (dual trend) or an alarm
summary screen can be displayed, too. A functional jog dial
allows quick selection of screens.
- Storage of measured
data
The measured
data (maximum 654,000 data) are stored in the 1.2MB internal
memory by 6 kinds of storage mode. The measured data can be
copied from the internal memory to a 3.5" floppy disk. Total
200 of message event and alarm event can be
stored.
- Easy processing of measured
data
Various kinds
of screen make management and processing of the measured
data easy. The historical data, which have been stored in
the internal memory or saved in the floppy disk, can be
displayed and compared. A search function of the specified
data is provided.
- Two models of continuous input
type and standard input type
Two models, continuous input type (measuring
cycle about 0.1 second/4-point) and standard input type
(measuring cycle about 5 seconds/6-point), are offered for
various applications.
- Safety sandards
The recorders are conformed to
CE-marking, UL (approval pending), and CSA (C-UL) (approval
pending). The door and bezel are protected.
(IP54)
- Easy settings
The interactive system on the
window opened by selecting items from the menu screen allows
easy programming. Using the engineering port, you can easily
set up the parameters by using the parameter programming
software [PASS] through a personal computer,
too.
- Data management by message
function
Messages
(maximum 30 alphanumeric characters) can be written on the
trend screen. Up to 10 kinds of message can be
pre-registered and written by the keyboard, communications,
or remote contacts. The message can be written on the
historical trend screen, too.
- Communications
The optional communications
interface are RS-232C, RS-422A and RS-485 using the MODBUS
protocol. The MODBUS communications link makes the system
configuration with your personal computer.
- Package software
The data
acquisition software [KIDS] and the parameter
programming software [PASS] are optionally prepared for
easy data management by your personal
computer. |
|
Models
| Types |
Input
points |
Input
speeds |
Models |
| Standard input type |
6-point |
5
seconds/6-point |
BR1761-N00 |
Continuous
input type
|
1-point |
0.1
second |
BR1713-N00 |
| 2-point |
BR1723-N00 |
| 3-point |
BR1733-N00 |
| 4-point |
BR1743-N00 | Communications
interface of RS-232C, RS-422A or RS-485: Option 2-port
communications is available. (option)
Specifications
| Measuring points |
Standard input type |
6 points |
| Continuous input type |
1, 2, 3 or 4
points |
| Input signals |
Universal input (DC voltage 10 kinds,
Thermocouple 36 kinds, Resistance thermometer 11 kinds,
DC current (by shunt resistors) |
| Range setup |
Programming of input types and ranges by the
keyboard. The measuring range is automatically selected
by the range programmed. |
| Scale setup |
Programming of maximum values, minimum values and
engineering units from the keyboard. |
| Accuracy rating |
0.1% 1 digit (DC voltage input) |
| Measuring cycles |
Standard input type |
About 5 seconds/6-point |
| Continuous input type |
About 0.1 second/4-point |
| Reference junction compensation
accuracy |
K, E, J, T, N, Platinel |
Maximum 0.5 |
| R, S,
Ni-NiMo, AuFe-Cr, WWRe5-26, WWRe0-26, U, L |
Maximum 1.0 |
| (The above errors are added to the accuracy
ratings for the internal reference junction
compensation.) |
| Burnout |
Detection of signal disconnection for
thermocouple inputs and resistance thermometer
inputs Up-scale burnout, down-scale burnout or
burnout disabled is selectable for each
input. |
| Input resistance |
Thermocouple inputs |
About 8M |
| DC voltage inputs |
Less than 2V: about 8M , 5V to 50V: about 1M |
| Allowable signal source
resistance |
Thermocouple inputs (burnout disabled) DC
voltage inputs(maximum 2V) |
Maximum 1k |
DC voltage inputs ( 5V to 50V) |
Maximum 100 |
Resistance thermometer inputs [Pt100(1),
PT100(2), JPt100] |
Maximum 10 per wire 3 wires - same
resistance |
| Input correction |
Zero, span and shift adjustments for each
channel |
|
Display |
5.5"h TFT color LCD (320 x 240 dots:111.36mm
x 83.52mm) |
| Trend display colors |
10
colors (selectable) |
| Operation screens |
Screens are switched by scroll key and
entry key. Maximum 5 groups except alarm summary screen
can be switched and displayed. (Maximum 6
channels/group) |
| Trend screens (with scale plate and pointer
displays) |
Selects from real-time trend, historical trend
and dual trend screens Vertical or horizontal time scale orientation
selectable Data display enabled or disabled
selectable Scrolling available Zone recording,
compressed/ expanded recording |
| Bargraph screen |
Data display enabled or disabled
selectable |
| Data screen (Data + Tag + Engineering unit +
Alarm activation status) |
| Multi-screen |
Real-time trend screen + Bargraph screen + Data
screen |
| Alarm summary screen |
Current alarm output status and alarm log
(channel, level, alarm event time) |
| Skip function (Trend and Data screens) |
The channels to be skipped in display can be
programmed for each group. |
| Replay (Historical trend) |
Historical data is displayed by specifying a
file.Data logging is continued. * Replay by scrolling
or by time specified * Enable to replay from a floppy
disk |
| Scroll
function |
Referring to historical data by the cursor is
enabled on the trend screens. |
| Data search function (Historical trend) |
The trend display position matching the following
conditions is searched automatically from the data in
the replay file and the cursor is moved to the
position.
- Channel A data = Channel B
data
- Channel A data <
Channel B data
- Channel A data < Data
specified (optional programming)
- Data of Channel A >
Data specified (optional programming)
- Data 1 specified (optional
programming)
Data of
Channel A Data 2
specified (optional programming) |
| Message display |
Displays messages on the trend screen through the
keyboard or by remote contacts signal and stores them as
a message dada file (maximum 200 messages). Enables
to display and stores them on the historical trend
screen. * Messages can be pre-stored. (maximum 10
messages, maximum 30 characters/message) |
| Display updating intervals |
Trend screen |
Depended on time scale programmed, minimum 1
second |
| Data
Screen |
Continuous
input type: about 1 second, Standard input type: about 5
seconds |
| Time scale programming |
Programs interval of displaying dots on the time
scale. 0.1, 0.2, 0.5, 1, 2, 3, 5, 10, 15, 20, 30 seconds
(Continuous
input type only: 3 seconds or shorter), 1, 2, 3. 5, 10,
15, 20, 30 or 60 minutes |
| LCD saver |
When no key is operated for the specified period
of time, the back-light is dimmed and the screen saver
display appears. |
| Programmable period |
1
to 60 minutes |
|
Internal
memory |
1.25MB |
| Storing
interval |
0.1, 0.2, 0.5, 1, 2, 3, 5, 10, 15, 20,
30 seconds, 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes (0.1
to 3 seconds: continuous input type only) |
| Storing data |
Measured data (Maximum 5 files on
simultaneous storage), Message (1 file), Alarm event (1
file), Programmed parameters (1 file)
- Measured data - File
number, storage start date/time, Storage interval,
Scale data, Measured data
- Message - Time, Message
text (Max. 200 messages)
- Alarm event - Alarm event
time, Channel, Level, Alarm type (Maximum 200
information)
- Programmed parameters -
Storage date/time, all parameters (Updated at
reprogramming)
|
| Measured data stored |
2-bite binary/1 data * Stores both
minimum values and maximum values in case that the
storing interval is longer than the measuring
interval. (For the
standard input type programmed with the storing interval
other than 5 seconds and for the continuous input type
programmed with the storing interval other than 0.1
second. ) |
| Storage into internal memory |
Manual operation (Keyboard) Trigger
signal (Remote contacts, Alarm
activation) Storage
during conductive signal ON (Remote
contacts) Start/end by time (End through the keyboard
is enabled.) * A file is closed when it has been
fully written. (The storage to the specified file
ends.) |
| Status output |
When 90% of the storage space in a
file has been written, the status can be output at alarm
output terminals. |
| Memory usage display |
The amount (%) of memory used in each
file is displayed on the operation screens. |
| External memory medium |
3.5" floppy disk (2HD: 1.44MB MS-DOS
formatted) Data in
internal memory can be copied to a floppy disk through
the keyboard. |
| Alarm types |
High alarm, low alarm, differential
high alarm, differential low alarm, rate-of-change
increase alarm, rate-of-change decrease
alarm |
| Alarm programming |
Individual programming for each
channel, Maximum 4 levels/channel |
| Alarm storage |
Storage of alarm event time and alarm
types |
| Alarm output (option) |
6 points |
| Rated power voltage |
100 to 240VAC, 50/60Hz |
| Power consumption |
Maximum 45VA |
| Power failure protection |
Programmed parameters stored into EEPROM memory,
Data stored into flash memory, Clock circuit and data
sustained for minimum 6 years by a lithium battery (at
the operation more than 8 hours/day) |
| Environmental conditions |
- Reference operating
condition
|
| Ambient temperature/humidity range |
21 to 25 , 45 to 65%RH, |
| Power voltage |
100VAC 1% |
| Power frequency |
50/60Hz 0.5% |
| Attitude |
Left/right 0 degree, Forward tilting 0 degree,
Backward tilting 0 degree |
| Warm-up time |
More than 30 minutes |
- Normal operating
condition
|
| Ambient temperature/humidity range |
0 to 50 , 20 to 80%RH On using a floppy disk: 5 to
40 |
| Power voltage |
90 to 264VAC |
| Power frequency |
50/60Hz 2% |
| Attitude |
Left/right 0 degree, Forward tilting 0
degree, Backward tilting
0 to 20 degrees |
| Weight |
About 3.2kg |
| Alarm output (option) |
6
points |
- International safety
standards
| CE-marking |
EN55011 Group 1
Class A, EN50082-2, EN61010-1+A2 |
| UL |
UL3111-1
(approval pending) |
| CSA (C-UL) |
C22.2 No.1010
(approval pending) |
| IP |
IEC529 IP54
(front) |
Options
|
Options |
Specifications |
|
Remote
contacts/alarm output |
Remote Contacts |
The
following operations are available by contact
input (4 points) and common (2 points) signal.
(parameter connection)
| (1) |
Data memory
trigger When
the conduct signal is changed to ON from OFF,
the data storage into the internal memory
starts. |
| (2) |
Data memory
signal During
ON of the conduct signal, the data is stored
into the internal memory |
| (3) |
Message
display When
the conduct signal is changed to ON from OFF,
pre-registered message is
displayed. |
| (4) |
Totalising
reset Reset of
the totalising data (All channels
together) | |
|
Alarn Output |
Independent
output at alarm activation: 6 points
| Contact
rating |
MOS relay
output |
240V(AC,DC) 50mA
resistive load |
| Mechanical relay output* |
100VAC 0.5A
resistive load |
| 240VAC 0.2A
resistive load |
| 100VDC 0.3A
resistive load |
* Not
conforming to CE-marking, UL and CSA
(C-UL) |
|
Communications |
RS-232C,
RS-422A or RS-485 (to be specified) MODBUS
protocol (RTU/ASCII) Functions: Data
transmission, Parameter programming, Operation,
Data communications input |
|
2-port
communications |
For a host
computer: Refer to the above For low-order
communications: By connecting with CHINO's
instruments, treats the data from the instruments
as the data communications input. Low-order
communications: RS-422A or RS-485 (to be
specified) Instruments: Recorders - BR1000,
AL3000, AH3000 Controllers - DZ1000,
DZ2000 MODBUS
protocol |
|
Mathematics |
The
following maths functions can be applied to the
measured data. The maths functions can be also
applied to the calculated data. (1) Arithmetic,
(2) Square root, (3) Logarithm, Natural
logarithm,(4) Exponential, (5) Maximum, minimum,
average, (6) Temperature/humidity |
|
Totaliser |
Totalising measured data or calculated
data
| (1) |
Interval: 1 minute
to 24 hours or no interval |
| (2) |
Start time: 0 hour 1
minute to 23 hours 59
minutes | |
|
Daily report
file |
Creates a
daily report file by specifying channels, time
(optional time, max. 24 points) and the following
items. (1)Instant vale, (2) Maximum value in
block, (3) Minimum value in block, (4) Average
value in block, (5) Maximum value in day, (6)
Minimum value in day, (7) Average value in
day |
|
Shunt
resistor for current input |
For
measuring current by adding 250 or 20 | |
Model
RZ-TPS01 Power Supply Unit for transmitters
This unit, which is designed for back-to-back
mounting to a recorder, is a dc power supply unit for up to 6
transmitters.
Features
- Direct supply of power to transmitters up to 6 sets
- By using this unit, the dc power is supplied from the
recorder to transmitters directly. The separate dc power
supply for transmitters is not needed.
- The unit being manufactured under ISO9001 is designed to
conform CE-marking.
- A circuit protector is provided for over load of output.
- For the safety wiring to transmitters, an individual
switch is provided for each output.
Specifications
| Power
supply |
100 to 24VAC,
50/60Hz |
| Power
consumption |
Maximum 32VA |
| Rating
output voltage |
24VDC |
| Rating output current |
Maximum 300mADC (total
current of all outputs) Maximum 50mADC (each
output) Each output not isolated |
| Weight |
About 430g |
| International safety standard |
CE-marking: EN55011 Group 1
Class A, EN50082-2, EN61010-1 + A2 |
| Applicable
recorder |
BR series graphic
recorder |
| |



|